Phone: +91 98332 29495
sales@sattvaengineering.com
The I Beam, made commonly from mild steel, features an I-shaped cross-section. It comprises two horizontal flanges connected by a vertical web. This design enables the I-beam to support heavy loads and distribute weight evenly over long spans and I-beams come in various sizes and specifications to meet different Structural requirements. The dimensions of an I-beam, including flange width, flange thickness, and web height, determine its load-bearing capacity and suitability for specific applications.
Sattva Engineering Explains here some essential points of I-Beam Dimensions and Their Importance do you know I-beams, also known as H-beams or universal Beams, are fundamental components in construction I-beams and H-beams available in large ranges or sizes of structures, from buildings to bridges
Key Dimensions of an I-Beam
The depth of an I-beam also called the height, is the distance between the top and bottom chords. This dimension is one of the most important dimensions when I-beam dimension and must be strong so it supports the load-bearing capacity of the beam. Many manufacturing companies do not have suffocation Knowledge of the dimensions of I-beams so that time which critical situations happen. A critical section is one where a critical or maximum stress occurs.Flange width is the horizontal measurement across the top and bottom sections of an I-beam. Wider flanges provide greater stability and bending strength.
Wide flange steel beams are available in a variety of width I Beam Sizes including: 4”-16” (10.2–40.6 cm), depths from 4”-16” (10.2–40.6 cm), flange thicknesses between . 35”-1.18” (9-30 mm), and a web thickness of . 25”-. 79” (6.5-20 mm) The web is the vertical section connecting the top and bottom flanges. The thickness of the web determines the beam’s ability to resist shear forces. A thicker web provides more shear strength, which is critical in maintaining the beam
When we select I-Beams size for our industrial project so that time we consent to few essential points such as determining the total load and live load per foot of beam and identifying the type of load you are supporting (roof snow, non-snow or floor) and match the total load and live load values to the values listed in the tables. The thickness and depth of the required member will be listed. To determine the appropriate I-beam size, start by considering the span length—the distance between the supporting points where the beam is installed.Longer spans require larger, stronger I-beams to prevent excessive deflection and breakage.
When selecting I-beams for a project, you can consider things like load requirements, material properties, and beam size buildings, colour coated, Construction, engineered building, polycarbonate panels, pre-engineered, pre-engineered structures, prefab buildings, steel structure, The first step in optimizing steel beam weight is to select the most suitable beam type for your design. There are different types of steel Beams, such as I-beams The next step in optimizing the weight of a steel beam is to use the optimal beam size for your design. Beam size refers to the cross-sectional dimensions of the beam, such as depth, width, flange thickness, and web thickness and web thickness.
Flanges: These are the horizontal elements at the top and bottom of the beam. They provide resistance against bending and support the load.
Web: The vertical element that connects the flanges. It helps to maintain the separation between the flanges and supports shear stress.
Flange Thickness: The thickness of the flanges affects the beam's strength and load-bearing capacity.
Flange Width: The width of the flanges contributes to the overall stability and support provided by the beam.
Web Thickness: The thickness of the web affects the beam's resistance to shear stress and bending.
I Beam is primarily used for Pre-engineered Buildings (PEBs) have a wide range of applications, including:
Factories and industrial buildings, Small manufacturing units, Warehouses and storage units, Small retail buildings, Commercial office buildings, Labor camps, Petrol pumps/service buildings, Schools, Community centers, Sports halls (indoors and outdoors), Living shelters, Workshops, Gas stations, Showrooms, Gymnasiums, Aircraft hangars, Metro stations, Outdoor stadium canopies, Vehicle parking sheds, Indoor stadium roofs, Bridges and railway platform shelters
We Supply I BEAM to Andhra Pradesh, Arunachal Pradesh, Assam, Bihar, Chhattisgarh, Goa, Gujarat, Haryana, Himachal Pradesh, Jammu and Kashmir, Jharkhand, Karnataka, Kerala, Madhya Pradesh, Maharashtra, Manipur, Meghalaya, Mizoram, Nagaland, Odisha, Punjab, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, Uttar Pradesh, Uttarakhand, West Bengal, Mumbai, Navi Mumbai, Pune, Nashik, Nagpur, Solapur, Kolhapur, Ambernath, Ahmednagar, Latur, Ahmadabad, Surat, Rajkot, Vadodara, Panaji, Madgaon, Chennai, Kolkata, Hyderabad, Bengaluru, Delhi, New Delhi, Ludhiana, Chandigarh, Raipur, Bhopal, Jamshedpur, Vishakhapatnam, Cochin, Ghaziabad, Noida, Gurugram, Bhillai, Durgapur, Vijayawada, Kanpur etc.
We Export I BEAM to Saudi Arabia, Iran, Iraq, United Arab Emirates, Qatar, Bahrain, Oman, Kuwait, Turkey, Egypt, Yemen, Syria, Israel, Jordan, Cyprus, Singapore, Malaysia, Indonesia, Thailand, Vietnam, South Korea, Japan, Sri Lanka, Maldives, Bangladesh, Mayanmar, Taiwan, Cambodia, Argentina, Bolivia, Brazil, Chile, Venezuela, Colombia, Ecuador, Guyana, Paraguay, Uruguay, United States Of America, Canada, Mexico, Panama, Costa Rica, Puerto Rica, Trinidad And Tobago, Jamaica, Bahamas, Denmark, Russia, Norway, Germany, France, Italy, United Kingdom, Spain, Ukraine, Netherland, Belgium, Greece, Czech Republic, Portugal, Hungary, Albania, Austria, Switzerland, Slovakia, Finland, Ireland, Croatia, Slovenia, Malta, Nigeria, Algeria, Angola, South Africa, Libya, Egypt, Sudan, Equatorial Guinea, The Republic of Congo, Gabon, Europe, Africa, Asia, North America, South America, Middle East, Far East etc.